DIY Miniature X-Ray Machine using a TV Vacuum Tube DY86
A simple rectifier tube can produce high-quality X-ray radiographs. It is a cost-effective way to explore the principles of medical imaging and vacuum tube physics in a controlled DIY environment.

Security X-ray systems at border crossings and airports work on the same basic principles as medical X-rays, but they are tuned specifically to identify materials rather than anatomy. In this project I will show you how I made a miniature X-ray machine with standard components that can be easily purchased on the market and at the same time their manufacturing cost is very low.
Even the manufacturing method is relatively simple, but for safety reasons I do not recommend trying to recreate it. X-rays are extremely dangerous to human health and if appropriate protective measures are not used, serious consequences can occur. Keep in mind that the X-ray radiation that we receive in our body remains forever and increases cumulatively with each new dose.
Generally, the X-ray machine consists of several components:
- A source of low DC voltage, in my case a laboratory power supply, and a battery can also be used.




In fact, this is the biggest advantage of this concept, since even the smallest dental x-ray tube costs several hundred dollars. The only downside is that the exposure has to last much longer due to the low radiation level, but in fact this is desirable in such dangerous DIY experiments. The DY86 tube is connected inversely, i.e. the cathode to plus and the anode to minus, which significantly increases its lifespan.

Even when exposed lasts longer than 1 hour, the tube temperature does not exceed 30 degrees - that's why this is called a cold emission.
- And finally, the medium on which the image is formed, specifically for that purpose I use dental film and appropriate chemicals for developing and fixing the image.

My first goal was to make the DY86 tube start emitting x-rays. I had several flyback trafos from old CRT monitors at my disposal, which generate DC high voltage at the output. I also purchased 7pcs. DY86 tubes, 3 of which had lost their vacuum from standing for a long time. There is a trick to test the vacuum: with a plastic stick, we hit the glass of the tube, and if the sound is ringing, the tube has good vacuum, and if the sound is dull and muffled, that is a sure sign that the tube is unusable. Unfortunately, during the experiment I "managed" to destroy 3 Tubes and only with the last one did I reach the desired result. Namely, directly with a flyback transfo it is very difficult to make the tube emit X-Rays. In fact, at a certain point it may start emitting but soon after, due to the fact that the voltage in these transformers is too low, and the current is too high, the Anode quickly overheats and the lamp is then destroyed. The solution is a line-type HV transformer without a cascade that outputs AC voltage, to which a voltage multiplier is connected. In this way, very high voltages are obtained with low currents. Through experimentation, I found the "sweet spot" so that the highest radiation is obtained with relatively low consumption. This is very important considering that when forming the X-ray image, we have to expose the film for a very long time to these relatively weak X-rays.
And let me immediately mention that all protective measures should be taken because this is very dangerous invisible radiation that has very harmful consequences for human health. The tube should be surrounded by a lead plate with a thickness of 1mm or more with a opening on the side where the film will be located. We are also not allowed to stay in the room where the experiment is being performed. It is even preferable to turn the X-ray machine on and off remotely. Below you can see a short clip of the moment when X-rays begin to be emitted.
Here is what the final version of the container that houses the X-ray generator, i.e. the DY87 tube, looks like.

On three sides there is a protective lead plate, and in front there is an opening of which the object that we are recording is placed. Since we are working with extremely high voltages, specially insulated wires are used, which also need to be spaced apart from each other, as well as from the shield. I place the object at a distance of 10 to 15 centimeters from the source and start the irradiation. The exposure time depends on the intensity of the x-rays and the distance from the source.
Specifically, I get the best results with the following parameters:
- Distance from the source 10cm (at that point the radiation has an intensity of about 200µSv)
- and Exposure time from 30 to 60 min depending on the object we are imaging (for objects with thicker and more impermeable material the exposure is longer).
When the exposure is over, we move on to film processing. This is done in a completely dark room, possibly slightly illuminated with a discreet red light source. For this purpose, I use 3 red 5mm LEDs.








SAFETY NOTES: Due to the extreme health risks involved, this video is for educational and documentary purposes only. X-rays are very dangerous ionizing radiation. They are invisible and pass through human body, and they can cause fatal diseases. Do not attempt to recreate this experiment at home. If you decide to carry it out despite the warning, I take no responsibility for your injuries - you do everything at your own risk.