Simple tool to assess inductors and transformers with 100nH < L < 100H+
- Have an unknown inductor/transfomer? - A digital scope ..then with a tiny simple circuit and a pocket calculator you may quickly get the inductance, number of windings amount of losses using a tiny circuit in addition. Here it is described how !
The method is old.
In the detailed description a very simple but versatile circuit is shown to support this method and examples are given of what can be measured and how.
This covers a small 8 turns copper coil 300 nH up to and 8000 winding transfomer core with 100 H. The only parameter to be adapted is the time base of the oscilloscope.
The description, the schematics and the examples with traces and results all are shown in the attached description.

Discussion (2 comments)